The Influence of Liquid Tanks on the Seismic Response of Isolated Structure
Program
Authors
Advisor
Date
Language
Type
Publisher:
Journal Title
Journal ISSN
Volume Title
Abstract
This study investigates the influence of liquid tanks on the seismic response of a Lead Rubber Bearing isolated structure under six near-fault ground excitations. Liquid tanks with various sizes and aspect ratios located on the base floor were used to assess the effect of sloshing on the seismic response. The response history analysis of the building model was performed with a MATLAB script. The sloshing effect of liquid was considered by using a mechanical modeling of liquid tanks with rigid walls. The structural response was analyzed using the selected ground acceleration records. The response parameters, such as hysteresis loops, bearing displacement, story drift of the structure, and liquid sloshing displacements, were investigated. The analysis results show that large bearing displacements were observed for building models with slender tanks subjected to earthquakes with high Peak Ground Displacements (PGD).
Description
▪ Yüksek lisans tezi.