Abstract
In recent years, the call control structures in earthquake using energy dissipating devices such as dampers
have been of particular importance. Research has shown that the use of viscous dampers can play an
effective role in monitoring the response of structures against the wind, explosion and earthquake. The
optimal arrangement is very effective damper efficiency of their performance. In this study, design is
ideal viscous damper damping operation for 100 percent and put it in different modes in structures using
software ETABS2015 try to determine whether the optimal model can be offered to install dampers in
plan and elevation classes, to be answered. The model used in this study is a 20-storey reinforced concrete
three-dimensional structure of the records used for non-linear time history analysis of earthquake KOBE
and SMART1 and are LANDERS. The results show the effect of the optimal arrangement of viscous
damper in reducing the seismic response of structures. However, the optimal location for a viscous
damper structure under different earthquake quake because of different characteristics vary. Therefore, it
can be a hundred percent for the optimal location pattern presented viscous dampers. LANDERS
structures under earthquake model in this study will have the seismic response of the maximum amount
of 43.02 percent compared to non-damper. However, in most cases, the best structural response is the
time when the dampers in building frames with each other in adjacent springs are installed.