Publication:
Failure of the Maintenance Gantry of a Metro Crossing Bridge

dc.contributor.authorVatansever, Cüneyt
dc.contributor.authorYAZICI, GÖKHAN
dc.contributor.authorSEÇKİN, EDİP
dc.contributor.authorAlçiçek, Haluk Emre
dc.date.accessioned2022-11-29T08:00:40Z
dc.date.available2022-11-29T08:00:40Z
dc.date.issued2020
dc.description.abstractThis paper investigates the failure of the underdeck maintenance gantry of the metro crossing bridge in Istanbul, Turkey on January 4, 2014, which resulted in the injury of four workers. First, a brief description of the gantry and the bridge has been provided, which is followed by the findings of the on-site investigation which involved the review of the video record of the incident, interviews with the field staff, overview of the project drawings and the investigation of the parts of the collapsed gantry. Additionally, the finite element model of the part where the collapse initiated was created and loaded in accordance with the operation procedures of the gantry during the incident. Finally, on-site investigation and finite element analysis results revealed that collapse of the gantry occurred by exceeding the shear capacity of the bolts in the connections. Moreover, the exceedance of the shear capacity was the consequence of unexpected operating practices used by the workers during the incident, which caused unforeseen shear stress concentration in the bolts.en
dc.identifier110
dc.identifier.citationVatansever, C., Yazıcı, G., Seçkin, E., & Alçiçek, H. E. (2020). Failure of the maintenance gantry of a metro crossing bridge. Engineering Failure Analysis, 110, 104436.
dc.identifier.issn1350-6307
dc.identifier.scopus2-s2.0-85079525807
dc.identifier.urihttps://doi.org/10.1016/j.engfailanal.2020.104436
dc.identifier.urihttps://hdl.handle.net/11413/7983
dc.identifier.wos000515523600020
dc.language.isoen
dc.publisherPergamon-Elsevier Science Ltd.
dc.relation.journalEngineering Failure Analysis
dc.rightsinfo:eu-repo/semantics/restrictedAccess
dc.subjectUnderdeck Maintenance Gantry
dc.subjectGantry Failure
dc.subjectAccident Investigation
dc.subjectMetro Crossing Bridge
dc.titleFailure of the Maintenance Gantry of a Metro Crossing Bridgeen
dc.typeArticle
dspace.entity.typePublication
local.indexed.atwos
local.indexed.atscopus
local.journal.endpage10
local.journal.startpage1
relation.isAuthorOfPublication1823c215-6059-4389-b995-9d5d7e6a61bb
relation.isAuthorOfPublication1447c0c0-6da8-494c-9e90-967a89d562d3
relation.isAuthorOfPublication.latestForDiscovery1823c215-6059-4389-b995-9d5d7e6a61bb

Files

Original bundle

Now showing 1 - 1 of 1
No Thumbnail Available
Name:
Tam Metin/Full Text
Size:
3.56 MB
Format:
Adobe Portable Document Format
Description:
Get Access

License bundle

Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.82 KB
Format:
Item-specific license agreed upon to submission
Description: