Publication:
A pipeline for adaptive filtering and transformation of noisy left-arm ECG to its surrogate chest signal

dc.contributor.authorTanneeru, Akhilesh
dc.contributor.authorLee, Bongmook
dc.contributor.authorMisra, Veena
dc.contributor.authorMohaddes, F.
dc.contributor.authorZhou, Y.
dc.contributor.authorLobaton, E.
dc.contributor.authorAKBULUT, FATMA PATLAR
dc.date.accessioned2020-08-05T22:19:51Z
dc.date.issued2020-05
dc.description.abstractThe performance of a low-power single-lead armband in generating electrocardiogram (ECG) signals from the chest and left arm was validated against a BIOPAC MP160 benchtop system in real-time. The filtering performance of three adaptive filtering algorithms, namely least mean squares (LMS), recursive least squares (RLS), and extended kernel RLS (EKRLS) in removing white (W), power line interference (PLI), electrode movement (EM), muscle artifact (MA), and baseline wandering (BLW) noises from the chest and left-arm ECG was evaluated with respect to the mean squared error (MSE). Filter parameters of the used algorithms were adjusted to ensure optimal filtering performance. LMS was found to be the most effective adaptive filtering algorithm in removing all noises with minimum MSE. However, for removing PLI with a maximal signal-to-noise ratio (SNR), RLS showed lower MSE values than LMS when the step size was set to 1 × 10−5. We proposed a transformation framework to convert the denoised left-arm and chest ECG signals to their low-MSE and high-SNR surrogate chest signals. With wide applications in wearable technologies, the proposed pipeline was found to be capable of establishing a baseline for comparing left-arm signals with original chest signals, getting one step closer to making use of the left-arm ECG in clinical cardiac evaluations.
dc.identifier9tr
dc.identifier.issn20799292
dc.identifier.scopus2-s2.0-85085528184
dc.identifier.scopus2-s2.0-85085528184en
dc.identifier.urihttps://hdl.handle.net/11413/6355
dc.identifier.wos000549854600165
dc.identifier.wos549854600165en
dc.language.isoen_UStr
dc.publisherMDPI AGtr
dc.relation.journalElectronics (Switzerland)tr
dc.rightsAttribution-NonCommercial-NoDerivs 3.0 United States*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/3.0/us/*
dc.subjectAdaptive Filtering
dc.subjectECG Transformation
dc.subjectFilter Optimization
dc.subjectLeft-arm ECG
dc.subjectSingle-lead ECG
dc.subjectWearable ECE Armband
dc.titleA pipeline for adaptive filtering and transformation of noisy left-arm ECG to its surrogate chest signal
dc.typeArticle
dspace.entity.typePublication
local.indexed.atscopus
local.indexed.atwos
local.journal.issue5tr
relation.isAuthorOfPublication16c815c6-a2cb-439b-b155-9ca020f8cc04
relation.isAuthorOfPublication.latestForDiscovery16c815c6-a2cb-439b-b155-9ca020f8cc04

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
A pipeline for adaptive filtering and transformation of noisy left-arm ECG to its surrogate chest signal.pdf
Size:
5.53 MB
Format:
Adobe Portable Document Format
Description:

License bundle

Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.82 KB
Format:
Item-specific license agreed upon to submission
Description: